Problems solved with release: 11.1.1054
Build: 11.1.1054
Release Date: 24th August 2009

ID

TOPIC

PROBLEM SOLVED

5264

WinCE OS

Movicon would freeze when changing languages in those devices where the Windows explorer server was not active in the system image (i.e. the latest VIPA panel images).

 

5536

Screen Objects

The Alarm Banner object would send the Movicon application into error closing it with an exception.

 

 

Minor Problems

ID

TOPIC

PROBLEM SOLVED

5540

Setup

The setup in Italian would not install all of symbol library categories.

 

5436

Design

When attempting to import windows vectorial and meta files (.wmf or .emf) on screen an "incorrect parameter" error message would show.

 

5454

Tools

No warning message would show when trying to import or export variable databases from encrypted or compressed projects  with the "CSV Tag Importer/Exporter" tool. Now a warning message shows stating why project file could not be read.

 

5470

Design

Movicon would not startup correctly when launched with the CTRL key pressed down. The development environment would not shoe and a Movicon.exe process remained pending.  This problem started happening with the 11.1.1053 version.

 

4429

OPC Communication

The write of OPC XML DA boolean type variables would fail.

 

5563

Tools

The string and variable import and export tools would not work in Windows Vista and Windows 7.

 

5460

Tools

Compatibility with Microsoft Excel has been added for CSV unicode files created with the import and export tool from the string and variable tables. One option in particular has been inserted so that the right separator chars are used according to the ANSI or UNICODE file type created by this tool and which is compatible with Excel.

 

5492

Setup

The "Restore" function for correcting installation errors would not restore symbols which had accidentally been deleted from the disk.

 

5501

Tools

The window would not shoe the vertical scroll bar for the project variable import/export tool.

 

5265

Users Management

A "Win32" project wizard would block the Movicon application in computers connected to a domain. This problem would not arise if the option for retrieving users from the local domain had not been set. In addition, the problem which impeded the use of the  "<UserName>@<DomainName>" syntax in a project logon window has now been fixed.

 

5484

Design

Resources set with the encription option would not get saved encrypted until modified. This problem started happening in the Movicon build 1017 and 1053.

 

5541

Screen Objects

The "Light" type objects with clickable properties would consume memory with each click.