Problems solved with release: 11.2.1083
Build: 11.2.1083
Release Date: 15th October 2010

ID

TOPIC

PROBLEM SOLVED

6554

Design

When selecting some of the Symbol Library categories, Movicon would raise an error (i.e. the Trend, Web viewers categories)

 

6605

Design

Movicon would raise an error while attempting to load .wmf file.

 

7233

OPC Communication

Movicon would raise an error running a project containing many tags to be published in the OPC Server address space (around 20000 tags).

 

6978

Real Time DB

Movicon would sometimes freeze when the project had two Data Loggers that recorded on change as well as having the same columns set for recording the same value.  

 

6871

WinCE OS

Problems occurred when using the Alarm Banner management in Windows CE that would cause the graphical interface to freeze in certain situations.

 

7166

WinCE OS

Loading png images in a Windows CE project would consume too much memory space.

 

 

Minor Problems

ID

TOPIC

PROBLEM SOLVED

7116

Alarm Management

Inserting a basic script expression in the alarms, the persistent file  (.alr) would not get created due to the string end character inserted by the expression manager.

 

5570

Alarm Management

The acoustic warning would not sound for alarms in 64 bit operating systems.  The audio card is now used for sounding alarm occurrences.

 

6924

Basic Scripts

The Display object's DisplayEditCmdTarget" interface's "FormatData" property settings would not get applied.  

 

6741

Basic Scripts

The On[Variable]Changed event would get suspended and would not reenter into action after a certain time had elapsed.

 

1460

Child Projects

A control used in child project screen, would use the parent project's homonymous variable when the child project screen was displayed as an embedded screen within a parent project screen.  Incompatibility: the variable in the context in which the resource is found is now used, which beforehand was searched for in the parent project.  

 

7072

Child Projects

A child project resource which used a parent project variable would not receive notification when this variable changed.  This problem concerned those resources that were initialized only when the variable changed (i.e. object events).  When a resource of this type used a parent project variable, the child project would not get notified of any variable value changes if they happened towards the end of the project startup phase.

 

6878

Child Projects

When a child project was set for connecting to a network Server, all the objects that had to recover the value from the variable's "Default Format" field, were unable to.  As a consequence, the controls used a null format.

 

6631

Design

Files inherent to the Communication Driver would not get managed correctly when inserting a project in the Movicon Source Safe.

 

6943

Design

Setting a textual report command in the Report commands and then adding the name of the template file in the "Textual Report : Layout File" field,  when reopening the command the same file name would appear in the "Textual Report: Destination file" field.  

 

7115

Design

The "Apply New Name" and "Apply Renamed Variables and Resources" command would not zero the alarm, data logger and "_c" files.

 

7099

Design

The "Exclusive Write Access" properties help string was not completely correct.

 

6842

Design

A symbol's "Regroup" command would not work correctly when the symbol's components had been set with a Command List in their "Commands on Click" execution property.

 

2561

Design

The basic script expression editor would not validate an expression when considered invalid, for instance, when using the "/" operator for dividing (division by zero in design mode is generated due to fact that variables are not initialized). Now, even if expression is not considered as valid because it cannot be resolved in design mode, a request to confirm or not is nevertheless shown.

 

6420

Design

The Alarm window's "Filter by Area" property would not display the list of areas until the project's alarm list was expanded.  

 

6117

Design

the asterisks would not show in some resources, such as the Basic Script, editor window's tab when the resource was modified.  

 

977

Design

The 'Embedded Screen' object would show the associated screen applying the zoom.  This behaviour showed while the "Embedded Screen" object was being loaded with its own embedded screen, applied with a zoom factor, was still opened in editing mode.

 

4795

Design

If the Movicon color selection window was open on screen, it would remain open when a window from another process was selected.

 

3310

Design

The 'Find' button from the main Movicon 'Tool Bar' would result disables no what context it was found in.

 

6624

Design

Copying and pasting a certain number of selected resources at the same time, the name of the last resource selected would be used as the reference name instead of the last selected resource's name.  Therefore all newly created resources would use the first selected resource's name.

 

6625

Design

In certain conditions in design mode the screen navigation bar would not display in screens requiring its use.

 

6845

Design

The "Check for Updates" command from the Movicon Symbol Library or Communication Drivers was case sensitive.  

 

7037

Design

In certain cases when modifying a variable a "beep" would sound, after which it became impossible to modify the variable's address.

 

6219

Design

Screen cross references would not always work properly.  

 

6740

Design

After having inserted a Dundas meter on screen, when modifying this object Movicon would not notice that object had been modified and would not check project for saving.

 

3206

Design

Dragging a variable onto a TraceDB window, an inquiry was made asking which animation option should be set instead of associating the variable directly to the window's  "Tag Table".

 

6680

Design

When a screen or basic script resource did not have a name in unicode chars, the "Separate thread (Open Safe)" or "Spawn in separate thread (Run Safe)" failed to work generating this message in the output window:

 

The file 'C:\DOCUME~1\Daniele\IMPOST~1\Temp\TFR10A.tmp' has been saved NOT with Unicode encoding while was containing Unicode text

 

3121

Design

After performing an "Undo" operation while editing a screen in development mode, all the screen objects associated to an invisible level became visible, even though all those levels that were disabled before the "Undo" operation remained disabled in the toolbar.

 

3954

Design

Symbols of variables with or without sign would show inverted in the Tag Browser window.  

 

3523

Design

The "Topic" parameter of a command from the "Help" category did not have a button for opening the string table's modal window used for easy String ID selecting.

 

6653

Design

The variable retentivity files (.var) and the persistent alarm files (.alr) were also saved in ANSI even though the project had been set in Unicode.

 

3478

Design

Fields relating to the report would remain displayed when IMDB Datalogger or Recipe properties were displayed.

 

7057

Design

Opening the Symbol Library and clicking on the "Toolbar Options" menu, a menu would appear containing an item with  <without title> written.

 

7053

Design

Accessing a screen's "Drawing object" list from the Project Explorer window and selecting a symbol contained within another symbol by ungrouping it using the command from the Symbol menu bar, Movicon would raise an error.

 

7114

Design

When a basic script expression was used outside a screen object, for example in an alarm or DataLogger, the variable's "Apply new command" command would leave the old name without applying the new one in the expression.

 

3351

Design

Screen background color filling would not fill completely using the "horizontal" gradient leaving a space colored with the screen's background color on the right hand side.

 

3292

Design

The Open Cross Reference command would not appear in both the main toolbar and View menu.

   

5044

Design

The "Tag Browser" window would display variables in the wrong group.  This problem would arise in projects that had complex group structures where some of the variables' names coincided with some group names.

 

6034

Design

A child project variable would get inserted on the parent project's variable list.  This would happen when a child project variable was modified using the Tab Browser window.  In this case the modification would also add the variable to the parent project's list.

 

6584

Design

When a project had a number of child projects embedded within each other, each with groups of variables using the same name, not all these variables would get displayed in the Tag Browser window.  

 

3522

Design

In a "Report-Recipe" command, corresponding to the "Data Logger-Recipe" parameter, the drop-down list showing all the DataLoggers or Recipes in the project would not appear to facilitate selecting procedures.

 

3124

Design

The control for accepting a new string ID in the "String Table" was not case sensitive.  For example, after having inserted an 'A' id, the "a" id would not get accepted.

 

7237

Design

The hatched area indicating area occupied by the Screen Navigation Bar in design mode would not get drawn with right proportions when applying the zoom to the screen.  

 

7204

Design

The "Project Explorer" window would sometimes remain on display when running project from the development environment.

 

2572

Design

When exiting the project, modifications to resources would be confirmed (Check-In) automatically in Source Safe.  Registry keys have now been added for modifying this feature.

 

6738

Design

The user interface would freeze when selecting a variable within the Movicon workspace and modifying the a structure prototype member type using the XML Code Explorer window.

 

2571

Design

When opening the "Variable List Window", the automatic check-out (extract...) would not execute as with other editing window for other resources.

 

2573

Design

The "Source Control" item would not appear on the menu which showed right mouse clicking on the "Navigation" resource.  This only happened for this resource.

 

181

Design

when selecting a parent project resource or variable in a child project property, the  "..\"  prefix would not be added to the name of resource to indicate that it referred to the parent project.

 

3071

Design

When copying-pasting a screen, the background image would not show in the screen when copied: it would only show when the project was closed and the reopened in development mode.

 

4831

Design

When inserting a symbol from the library that used variables and then selecting a variable field from the Dynamic Property Inspector window followed by pressing the OK button, the selected variable would not get added with an increasing index if one already existed in the RealTimeDB.   

 

4514

Design

When a Scheduler Window object slightly went outside the screen, it would start flickering.

 

3499

Design

The script editor window and the "Script Explorer" window support the "Open #Uses" command.  This command adds little numbered tags, "2, 3, etc", for each script module that has been included with the "'#Uses" command in the main "1" module.  Passing over to one of these modules, the modifications carried out would not be retained when the editor window was closed.  Now the secondary modules are opened in read only and therefore cannot be modified.

 

6946

Design

Symbols inserted from the Symbol Library would not get managed properly when changing Movicon versions.

 

3467

Design

Trend and DataAnalysis objects would start flickering when slightly going outside the screen boundaries.

 

6506

Design

The symbols in the Symbols Library would not get drawn when using the Antialiasing.

 

569

Design

Exploring a menu with the "Project Explorer" window, the menu and popup items were shown in alphabetical order and not in the programmed order.

 

6669

Design

Movicon would not load the ".uxp" file containing the user passwords when the project was run for the second time.

 

6175

Design

Memory leaked when using the "Tag Browser" window when called from the project properties window, then closed followed by closing the project as well without waiting for the property window to complete confirmation procedures.  

 

7006

Design

When Drag&Dropping a variable onto an object, such as the rectangle, some animation options appeared missing from the list for associating the variable which included:

 

Transparency

Text - Display Value

Images Animation

 

In addition, when you now Drag&Drop a variable onto a Trace or Data Analysis object while pressing down the CTRL key, the pen will be added to those already existing. Otherwise, if you don't use the CTRL key, all the existing pens will get deleted.

 

2863

Design

While creating a project using a Wizard within Movicon, any DataLogger that was created would get set with an age higher to those of the "MaxDaysAgeHistoric" and "MaxCacheBeforeFlush" constraints. However this would not happen to other DataLoggers added afterwards.

 

5707

DOM (Document Object Model)

The "NetworkBackupServerName"  property for reading/setting the Backup Network Server had not been included in the AlarmWndCmdTarget, DLRWndCmdTarget, HisLogWndCmdTarget, TraceDBWndCmdTarget, HourSelectorCmdTarget and RecipeWndCmdTarget interfaces.

 

6518

DOM (Document Object Model)

The  "DeleteRow" method from the "GridWndCmdTarget" interface would not delete the row if the cell had not been selected with the mouse beforehand.

6257

Networking

Enabling the Audit Trail of a structure variable and modifying the variable's members on the client side would record values as byte array types in the database.

 

1475

Networking

Executing a script from a remote debug session would not execute the script on the Server.  This malfunction would only show in the PowerHMI version.

 

3831

ODBC

The "ODBC Real Time I/O Link" feature would first execute an INSERT and if the INSERT failed, it would execute an UPDATE.  Now these two commands are execute in reverse sequence.

 

7315

OPC Communication

Movicon was unable to communicate with the OPC XML DA Servers which used the "ItemPath" attribute to identify the item.

 

7142

PowerHMI

Problems with the Chinese language in the PowerHMI version.

 

6841

PowerHMI

Comments on Alarm ACKs could be entered even though not supported by PowerHMI.

 

3357

Real Time DB

When defining two variables with the same Internal Address in the same shared area and then using them both in different basic expressions, when one of the two variable passed from the InUse to the Not Inuse state, the expression in the other variable would also stop being executed.

 

7211

Real Time DB

In very particular conditions Movicon would raise an error running a project with the statistics enabled in structure variables with enabled Intellisense.

 

7014

Real Time DB

If the two GetMemberObjectFromName and GetMemberObjectFromIndex functions from the DBVarObjCmdTarget interface were executed within the dropping code OnVariableCreated event, a nothing object would be returned.

 

7176

Real Time DB

A basic expression that used part of a text already existing in another expression would not get valuated in runtime.  For instance, one of the two expressions below would not have been resolved:

 

1) 1 + VAR00001 + 1

2) VAR00001 + 1

 

7012

Real Time DB

When changing the name of one of the members belonging to a structure prototpe, the member order would change by moving the changed member to the end of the list.

 

6759

Real Time DB

The "SetTimeStamp" function from the "DBVarObjCmdTarget" interface would not work for variables in shared areas.

 

5965

Recipes Management

While putting a project into run mode the following misleading message would show in the output window:

 

Cannot find the variable '' for the DataLogger/Recipe 'Recipe' Data Logger/Recipe

'Recipe' failed to initialize

 

In reality the recipe actually worked ok.

 

6903

Report Management

The follow ODBC message would show when executing the a XtraReport "Export" command in Windows 2008 64bit Server:

 

Error when trying to populate the datasource. The following exception was thrown: ERROR [IM002] [Microsoft][ODBC Driver Manager] Data source name not found and no default driver specified

 

6995

Report Management

The ReportViewerNET tool, used from command line or invoked by Movicon with the appropriated commands ("View report", etc), could not retrieve the ODBC DSN connection if running in a 64 Bit Operating System.

 

3914

Scaling Resource

The Normalizers would not work correctly when using 'integer' variables in normalizing.  this behaviour would happen due to rounding off the scaled result: Movicon considered the rounded off value in the scaled integer value, as a change to its value, a bilateral scaling effect, perceived as feedback to modify the source value of the raw variable.

 

6804

Screen Management

When screens were inserted in nested folders problems would start happening:

 

1) An Embedded Screen inserted in an nested folder would not manage the "Embedded Tag Screen" properly

2) The "Open Next" and "Open Previous" page change commands would not work with screens inserted in nested folders.

 

7046

Screen Management

When enabling the "Add Back Button" or "Add Back to Startup Button" property in the Screen Navigation resource, the navigation bar would also appear in screens had hadn't been inserted in the resource and, above all, in screens opened as Modules or Frames.

 

6970

Screen Management

When closing a screen opened in a separate thread, the last screen loaded or the startup screen would not re-open.

 

803

Screen Objects

When enabling the "Spawn thread execution" property and inserting a Chart object on screen, an error message referring to the "DrawChart.cpp" file would show when starting up Movicon in simulation mode.  The 'Chart' object no longer appears on screen and the following message appears in the output window:

 

(Failed to create chart. Make sure the object isn't inside a synoptic with the separate thread option).

 

6760

Screen Objects

When the "FitInWindows" property from the "SynopticCmdTarget" interface was modified in runtime, it would resize screen without having any effect on the screen objects.  

 

6551

Screen Objects

Instead of rotating the string as a whole, each object's text character would rotate singularly.

 

Incompatibility:

Text rotation will be treated with the new methodology for imported projects saved with previous versions.

 

1716

Screen Objects

Associating a Visibility Level to objects contained in an Embedded Screens would not change their visibility when the container screen's Layer Variable changed. The screen  had to be reloaded in memory to update the objects' visualization in the Embedded Screen.

 

6809

Screen Objects

The 'Enable Var.' and 'Status Var.' properties would always be hidden.

 

6794

Screen Objects

Movicon would raise an error in runtime when more than one Alarm Banner object had been inserted on one screen when the project's Heap memory management had also been enabled.

 

6564

Screen Objects

Problems would occur with public symbol heredities when using Embedded Screen objects.  Now the objects in Embedded Screen are updated using the public screen set in the screen containing them.  However, if no public screen has been set, the one set in the screen containing the Embedded Screen will be used instead.  

 

7255

Screen Objects

The "DataLogger/Recipe" window could not retrieve a recipe from a Network Server.

 

3028

Screen Objects

Local variables of a screen contained in a "Tab Group" object or "Embedded Screen" object would not show because they were searched for in the "Tab Group" or "Embedded Screen" object's container screens.

 

6732

Screen Objects

A variable's "Increase" and "Decrease" commands would change the variables average statistic value even though it had already reached one of the set limits.  For example, once  the set maximum value had been reached, attempts to increase the variable further would only increase its average statistic value while keeping its actual value unchanged.

 

7056

Screen Objects

An object's border would not draw correctly with the Antialiasing activated.

 

7157

Screen Objects

When an Embedded Screen object displaying a child project screen was inserted within a parent project screen, the Embedded Screen's String ID would not get resolved. The same problem also happened with object Images and Configuration files.

 

7196

Screen Objects

The "List Box" object would not draw the item list correctly if the screen had not been enabled with the 'Fit in Window' option.  

 

7251

Screen Objects

Display objects would not save current column settings in the external configuration file.

 

353

Screen Objects

The "Tab Group" and "Embedded Screen" objects would not adapt to screen if already in memory.  Therefore, the embedded screen contents would display over the embedded screen's borders instead of staying inside.

 

7171

Screen Objects

Opening a screen containing the Alarm Banner, the object would quickly scroll all the alarms in the system instead of just showing the last one.

 

5101

Screen Objects

A drawing configured to show only in a certain level, would not show when this level activated when drawing was within a symbol.

 

7010

Screen Objects

Movicon would raise an error changing page when the Trend was put into Pause mode and used Visibility Animation to hide it.

 

7034

Screen Objects

The Data analysis, Trend or screen print would not work if the Antialiasing had been enabled.

 

7140

Screen Objects

A Data Logger window object would always show all the associated Data Logger columns.

 

6611

Screen Objects

The object gradual filling would not work if the Antialiasing had been enabled.

 

6921

Screen Objects

If the "Area Filter" property had been set in the Alarm Window object of a project containing a large number of alarms (i.e. 1000 and more), the active alarm list would take a few seconds longer to populate when opening the Alarm window to view.

 

6945

Screen Objects

The 'Radio button' object would not accept empty strings as the first list item in the "Object Title" property.  In fact if the first Item (the object's Title text) was an empty string, all the other option items would not get shown.

 

6862

Screen Objects

Screens used for Numeric or Alphnumeric pads, Get Password and Expired Password dialogs would open up in the position where mouse was clicked on and not in the centre of the screen.

 

4889

Screen Objects

The Display window's "Choose Field" window would not close automatically if exiting from the screen or saving the project.

 

1320

Screen Objects

Columns set in a "DataLogger/Recipe" window would disappear after a change language.  Incompatibility:  1) Opening a project saved with a previous version might not show all the columns until project is saved again.  2) The "DataLogger/Recipe" window does not have reverse or downwards compatibility if saved with current version.

 

6817

Screen Objects

Some objects (Imbedded Screen, TraceDB window, Recipe Manager window) would not show all variables when public symbols.  

 

6818

Screen Objects

The 'IP Telecamera Refresh Time Variable' property would display based on the "Preserved Commands" property settings when the symbol was made public.  When the "Preserve Variables" property was enabled, the 'IP Telecamera Refresh Time Variable' property would only show if the "Preserve Commands" property had been enabled as well.

 

6823

Screen Objects

An object's Dynamic Image animations would send Movicon in error if the list of images was empty.

 

6982

Screen Objects

When the antialiasing was active, the arrows and dotted lines would not be drawn correctly.  

 

6951

Screen Objects

The Recipe Manager object's  "Execution > Project" execution property would not be retained after being set.

 

6947

Screen Objects

Using a scheduler Window with the "Variable" column enabled for allowing variable modification in runtime, the variable selection list remained empty if a child project had been linked in the project.

 

7104

Screen Objects

The dynamic tooltip would ignore the format of a variable value.  The dynamic format now shows the value with the format set in variable and not in any control.

 

6896

Screen Objects

Switching to runtime mode and back again into development mode the text displayed by the IP Camera viewer object was the last text that was displayed in runtime.

 

6694

Screen Objects

It became impossible to change the measure value text color making values difficult to read when object had a dark background color.

 

6937

Screen Objects

Locked symbols could nevertheless be modified when selecting them through the Project Explorer Window.

 

6992

Screen Objects

The "Samples" property from the "TrendCmdTarget" interface could not be set with a value superior to 10000. This value can be exceeded by the Data Analysis object but not the Trend object.

 

7152

Screen Objects

A command set to execute upon mouse button release an object would not get executed if the object was a symbol component and the mouse moved before button was released.

 

6984

Screen Objects

If the alphanumeric pad for inserting passwords opened for default or in custom mode when using the custom password dialog pads, would permit passwords entries without substituting password with astericks.

 

6948

Screen Objects

An error would generate when inserting the start time in the Scheduler Window object in grid mode even though time was correct.  This would happen if the end time was entered first when both the start and end times were the same.  

 

6915

Screen Objects

Prints activated with a screen "Print" command would not print all the screen's objects (for instance, 3D buttons, Dundas meters etc.).

 

6902

Screen Objects

A problem would occur in the Scheduler window overlapping graphics when setting button alignments to an option other than  'bottom' with the 'Scheduler Selection comboBox', 'Add Scheduler Button' or Remove Scheduler Button' enabled as well.

 

7209

Tools

The "HisLogUpdate.exe" tool would raise an error at project startup when the project being run had been set a link to a missing child project.  

 

7235

Tools

Importing variables with the "Csv Tag Importer/Exporter " pool would fail in certain conditions raising the "The read row is too long!" error when too many variables were involved.

 

6672

Tools

Problems with reading the runtime user's ".rtuser" file when reading when project had been set as Unicode or Crypted.   

 

7169

User Interface

When changing document (screen, basic script, etc.) in the Movicon workspace by clicking the mdi tab, the resource that opened would close straight afterwards.  This would happen when clicking on the same position where the 'x' to close tab appeared when opened.

 

7268

WebClient

When connecting different WebClient sessions using PCs with Windows 2003 Server OS, the Movcion Server project's instance would suddenly close without giving an error.

 

2997

WinCE OS

In systems with WinCE some system string concerning the Numeric and Alphanumeric pads would not substitute correctly according to the string table.  The Sting IDs in question were:

 

_CANCEL_PADTEXT_

_DELETE_PADTEXT_

_OK_PADTEXT_

_CAPSLOCK_PADTEXT_