Problems fixed with the version: 11.5.1180

 

Build: 11.5.1180
Release Date: 26 February 2016

ID

TOPIC

FIXED PROBLEMS

15751

Redundancy

The user interface in a project enabled with redundancy would freeze when one of the PLCs connected to the Driver Stations was turned off.

 


Minor Problems

ID

TOPIC

FIXED PROBLEMS

14671

Alarm Management

In some cases the milliseconds reported in the Time columns of the Alarm Window and the relating Temporary Historical were wrong.  

 

16678

Alarm Management

The Alarm Banner would not update the current value of the variable inserted in the alarm text if the page, in which the Banner had been inserted, had not been reloaded.

 

16225

Basic Script

The GetTimeStamp() function from the DBVarObjCmdTarget interface would return the wrong data in cases when the system's minutes were comprised in the  >0 and <6 range.

 

14268

Data Logger Management

In some cases the RestoreFlushedData would not restore data correctly.  Note:  the tool used the "ODBCTokenForSpaces" registry key to identify the start and end characters for the column name used by the specific Data Base Gesture when the names contained spaces.  

 

15972

Data Loggers Management

Data Logger column names would duplicate when using the Copy and Paste from the Edit menu.  This would not happen when using the  CTRL+C and CTRL+V shortcuts.

 

16270

Design

The CTRL+SHIFT+S command for saving all the project's modified resources ('Save All') would not function.

 

16346

Design

The Contextual Help would not open in the DBVarObjCmdTarget's GetTimeStampMS() function.

 

16505

Design

When the Cross Reference List opened with a selected variable, even though the variable was still selected in RealtimeDB but without focus, it would get eliminated from the RealtimeDB when the Canc key was pressed.

 

15646

Design

The 'Create Recipe Screen' Wizard would not create the temporary variables with the correct names if the Recipe was set with Structure type variables.

 

14888

Design

When the Transparent Animation was linked to a Variable that changed value, the animation present in other objects would slow down when this happened.

 

15112

Design

The Grid object's  "ColumnsWidth" property would not function correctly when the Grid was populated by VB Script.

 

16477

IL Logic

"Logica IL" editor would lose any modifications that were not confirmed before being closed.

 

15323

Menu Resources

The 'Help failed to open' error  message would show when selecting the "Help Basic Script" item from the Help menu of a Basic Script Resource.  

 

16565

Networking

The Audit trace on the Networking Client side would provide the Server with information about the logged in user who changed the variable on the Client side even when the 'Enable CFR21-PART11' property had been set to true on that Client.

 

16025

Networking

The Client would go into server connection timeout without resolving the error.  Now the "Number of attempts to Connect" property from the "Advanced TCP Transport Settings" property group has been set to the 0 value (default 10) to allow the closing and reopening of a new connection socket to the Server's TCP/IP port after the number or retries has been reached in order to retrieve the Client project's connection Timeout error.  

 

14661

Networking

The Alarm Window of the Client configured for a contemporary connection to a Primary and Secondary would not connect automatically to a Secondary Server when the Primary Server was nolonger available.  In any case, even when the Secondary became unavailable the Client would not automatically retry to connect after a certain number attempts to do so in order to avoid causing an infinite loop of requests.  This made it necessary to update manually (F5).  

 

16591

Networking

The Movicon Windows (Such as the Alarm Window, Historical Log Window and the TraceDB window) that can be connected to a Networking Server would authenticate with the user used on the Client side for logging on to the Client application.  Now, when the Servers use a "Default User" for authenticating the Networking clients, the Movicon client windows use the authentication towards the Server independently from the user logged on to the Client in a certain instant.  

 

8364

Networking

Using the "Local Transport" would cause a delay in exchanging data between a Networking Client and Server project.

 

15153

ODBC

Activating the "ODBC Real Time I/O Link" option in a String type variable would cause ODBC errors such as 'incorrect syntax' in cases where the string variable contents were deleted and therefore resulted as being empty.

 

16576

OPC Communication

Movicon would raise an exception when closed after having execuing a failed search for an OPC Server UA.

 

15099

Real Time DB

When an alarm was set with an access mask other than the default value, a 'Resource Access Denied'  message would show upon acknowledging or resetting the alarm if there no user had logged on.  

 

15996

Redudancy

In cases where the Movicon "OPC Server" has been configured active in the Primary and Secondary project,  the OPC Server in the Secondary project would disable when the Primary project was active.  Now both the Priimary and Secondary OPC Servers are activated.

 

15674

Redudancy

The Startup Script would not execute when the Secondary Server reactivated in response to the unavailability of the Primary Server.  

 

15858

Redundancy

In case where structure variable members were exchanged with the field directly (enabling the activation option of each individual member), the member quality would not update correctly on the Secondary Server o on the Client the Primary Server changed.  In addition, when the "inherit Quality" property was set, those members not connected to the field would get set with the "Not Good"  quality when a communication error occured in the structure variable but they would not get reset back to the "Good" quality when the error was resolved.

 

16074

Redundancy

The Startup Script would not execute on the Secondary Server if the Script resource  "Run on Server" property had been purposely disabled and if the Primary Server was activated correctly.

 

14993

Redundancy

When the "Switch on (on Secondary) Driver error (of the Primary Driver)" property was active, the Secondary drivers would switch off instead of switching over from the Primary when the Primary was nolonger available in network.

 

14721

Screen Management

An error would occur in the Movicon .cpp modules when using Windows 8 and CoDeSys Driver versions prior to 11.4.1.4

 

15320

Screen Management

The status viewer if enabled in objects would still continue to indicate the do not return off communication error after the communication error had been fixed.

 

15100

Screen Management

In Windows 8.1 it was not possible to interact with a Screen opened in Popup modale mode from a Screen with its "Enable Multi-touch2 option enabled.  However this problem would not occur when Popup screen was opend in Frame mode.

 

15990

Screen Management

The "Pinch & Zoom" management in Multitouch systems has been improved and is now more precise with smoother zooming in and out.

 

15102

Screen Managemet

A screen Button, that was set with the On/Off mechanics in Touchscreen systems based on Windows 8.1, once pressed would activate the off command in the variable when losing focus instead of remaining pressed.

 

16298

Screen Objects

Some Library Symbols would be redrawn incorrectly on screen when changes were made to their XML code using the XML code Editor.

 

15704

Screen Objects

The "Duty Manager" Template symbol would not handle the On call duty Group users' descriptions in alphabetical order in the Runtime Users file used for managing the send priorities of alarm notifications.

 

15197

Screen Objects

Tje 'Historical Log Window" had visualization problems setting a filter query in alarms using the 'Wuery' property from the "HisLogCmdTarget" interface.

 

16291

Screen Objects

Some symbols from the Symbol Library have been updated to signal their incompatibility with the WinCE environment by setting the  AvCE attribute ="0" in the node of the symbol in question.

 

16160

Setup

The new  IEC61850 Driver has been added to the list of avialable Drivers.

 

14456

Setup

The help file of the installed languages would not install correctly when installing Movicon in the development environment in Turkish together with another language.

 

16419

Tools

The Tag Importer-exporter Tools allowed the importing of Tags whose names contained characters that are considered invalid for creating variables in the RealtimeDB.

 

15932

Tools

The SMTP Plugin settings would get saved in a file with the same name of the Hark Disk volume in the Main Project files and not with the "smtp_direct.settings"name in the Project's DATA folder.

 

16017

Tools

The CEUploadServer tool launched on the WinCE Panel would go into error when cancelling the project folder from the WinCE device using the 'Delete Device Memory Card' button from the "Transfer Project to Device" utility.

 

15715

Tools

The Alarm Dispatcher would go into error when sending an email with a considerably long body text due to not handling the data from the alarm log correctly.

 

16026

User Interface

When Movicon.exe and MoviconRuntime.exe were started up from the Terminal Service as Clients, they would not startup or shut down immediately due to incorrect reading of the General "MaxAppInstances" key. Now when the"MaxAppInstancess" value is set to 0, there will be no limits to the number of Movicon instances that can be started up in the system.  Incompatibility: the  "MaxAppInstances" 0 value is incompatible with previous versions which interpret this value as no Movicon processes to be started up.

 

16128

WinCE OS

The links used for installing Movicon CE from the Windows Start Menu would not install the CABs correctly.