ID |
TOPIC |
NEW
FEATURES |
15295 |
Design |
An option has been added to execute
Startup Commands after starting up the loaded Drivers.
Basically, the command list is started up only after
all the variables connected in input have been exchanged
with the field. This option is only used when the
"Sync at Startup" setting has been activated
in the Driver settings.
|
16018 |
Historical Log Management |
The "MaxLengthFlushDBFile"registry
key has been added to the General section which functions
in the following way: 1. Without key: Movicon uses a default
lime of 100000 KBytes. 2. With Key = 0: Movicon will not
record on file and flushed data will be discarded. 3.
With Key > 0: if the file size is lower than the limit,
it will be flushed, if not the data will be saved on file.
When one of the flush file limit has been reached,
it will signalled in the Project Historical Log. |
16059 |
IMDB(In Memory DB) |
The value of the "Maximum
number of records" property concerning the resources
that use the IMDB engine is fixed at 10000 for default
instead of '0' for the WinCE platform to avoid memory
saturation caused by very frequent recording activity.
|
16294 |
License |
The gesture feature on the Crypkey
Software License has been updated to the 8020 version.
|
16356 |
License |
The Optional Driver option of
the Runtime key is nolonger considered by Movicon from
this version.
|
16126 |
Networking |
The Networking management has
been optimized in those occasions where a great number
of variables are exchanged. The variable communication
between Client and Server is now 7 times faster.
|
14935 |
OPC Communication |
The OPC Client UA and OPC Server
UA has been inserted for the for Data Accessing
project variables. |
16420 |
Screen Objects |
The Ungroup operations of a Symbol
would cause the loss of animation, VB Script, Logic or
Commands set in the Symbol's container without warning.
Now when these operations are performed a message
appears to inform users that certain data may be lost
at container level.
|
16485 |
Screen Objects |
The "EnableZoom" Booleana
property in the "SynopticCmdTarget" interface
has been added for enabling/disabling the Zoom operations
from the VBA context as well.
|
15939 |
User Interface |
The Dynamic Help Window is no
longer present in the Movicon IDE.
|
16118 |
WebClient |
It is now possible to use the
UserName and Password parameters at the end of the list
of parameters in the Applet Java for opening the service
directly without accessing the Browser. Therefore
the parameter list from command line is now: [Server]
[Screen] [Width] [Height] [Port] [UserName] [UserPassword]. |
14288 |
Dispatcher |
Added
the DWord value "DiagnosticLog" in the key HKEY_CURRENT_USER\Software\Progea
Automation \Alarm Dispatcher
which when set to '1' saves
the log files in message Text in the Movicon project folder
named "DispatcherDiagnostic ** - ** - **** _ ** _
** _ **. txt"
where
** - ** - **** _ ** _ ** _ ** contains the date and time
to the file creation. A
new file is created to overcome the 50K size. Are not
expected files delete criteria. The Log contains information
passed to Dispatcher from Movicon, and Dispatcher notifications.
This Log
with the Dispatcher's log(.dsplog) may give a more complete
information about dispatchering phases of the message
via plugins.
|