Problems fixed with the version: 11.5.1182

 

Build: 11.5.1182
Release Date: 11th November 2016

ID

TOPIC

FIXES

18071

Networking

The Client would not update 'In Use' variables and would subscribe to the Server if a variable with a disabled 'Enable Network Server' property existed in the Server for which the Client subscription would fail.  As a consequence the Client would make several attempts to subscribe eventually using the Backup Server causing the Networking communication to crash.

 

17707

Recipe Management

When a Recipe Index column had not been set with a varilable, a recipe activation command from the Recipe Manager Window would raise an exception in Movicon if the 'Always in Use' property had been disabled.

 

Minor Problems

ID

TOPIC

FIXES

17974

Accelerator Resources

In certain overstressed CPU conditions or when low performing devices were being used, the blink animations in objects would go out of sync.

 

17827

Data Loggers Management

When pasting and copying a Data Logger Column, a new column was created with the name of another column if selected while completeing the copy and paste operations.

 

18115

Design

The 'User Dialogs' library symbols would not create variables correctly once inserted in the project and therefore the symbols would not function properly.

 

17824

Design

When resizing an object, its sizes would modify with a tilted effect in respect to the resizing reference points.  

 

17948

Design

When setting the 'False' value within the VBA context of the Alarm Window, the 'bRet' parameter in the 'OnInsentOrUpdateAlarm' event would not inhibit alarms from displaying in the Alarm Window. .

 

17930

OPC Communication

When the secondary server activated In a redundancy and OPC DA communication configuration, it was unable to write in the OPC Server.  

 

17548

OPC Communication

Connecting to a CoDeSys or B&R OPC UA Server which exposed a structure deployed in the Address Space as OpcUa_NodeClass_Variable instead as  OpcUa_NodeClass_Object, the data selection window would not show the structure variable.

 

17117

Redundacy

When a network connection error occurred between the Primary and Secondary Server while communicating with a OPC Server, the Secondary would send data that had not been updated to the Primary, such as variable zero values, once the Networking communication was restored.

 

16578

Screen Management

When opening a PopUp, the data in the window underneath would not update.  In addition, when the Password request window opens, notification to the objects are briefly interrupted independently from the value set in the [General\DynObjPumpIteration] key that is now exclusively used for slowing down the variation notifications to the object,  This is very useful for hardware with insufficient resourses.  The default value is now  '0'.

 

17808

Screen Objects

Clicking on overlapped objects would open the password request window if enabled in the object directly underneath the one clicked on.

 

17688

Screen Objects

An object would only start being dragged when the mouse reached its border.  Now the dragging process starts immediately once the object is selected to do so.

 

17554

Screen Objects

When zooming a screen with objects enabled with the Dragging function, the set dragging limits would not change as a consequence to the zooming operations if the object was moved.

 

 