ID |
TOPIC |
NEW FEATURE
|
29807 |
Design |
A new General DWord32
"PrintLicenseReport" key has been added to print
License data in the System Log when value = '1'. The Default
value is '0'.
|
30769 |
Design |
A 'Refresh' button is now
available in the OPC UA Browser window to refresh the
connection to the selected OPC UA Browser. Once pressing
the Refresh button, the connection will close and reconnect
and you will need to repeat the navigation from the Server
tree of items exposed from its Address Space. The
connection can also be refreshed by pressing the F5 key
from the keyboard.
|
30768 |
Design |
There is now a 'Synchronize
OPC UA Server Tags' function to align the list of OPC
UA variables currently exposed by the Server. Two
situations may happen while synchronizing: Those Tags
not found on the OPC UA Server and not present in the
Movicon OPC UA Client will be added as new Tags. Tags
in the OPC UA Server and currently present in the Movicon
OPC UA Client will be updated with those in the Server.
A prompt will be given to cancel all those Tags
that are in the Movicon Project but are not in the OPC
UA Server. The Esc key can be used to abort the above
procedure.
|
30767 |
Design |
It is now possible to remove
the list of OPC UA Servers from the Project's OPC UA Client
Resource by using the CANC key on the keyboard or the
Mouse's contextual menu. The cancellation can be
annulled by using the Undo command from the Edit menu
or by using the "CTRL-Z" keys from the keyboard.
|
30582 |
OPC Communication |
Errors that return the OPC
UA Stack are shown with their description followed by
the error code.
|
30409 |
OPC Communication |
A new Action has been added
to the "Set OPC UA Endpoint" variable command
to allow the Endpoint value of a Project's OPC UA Client
Resource to be edited at Runtime. A new Action has
been added to the "Set Driver IP" variable type
command to allow new Primary and Backup TCP addresses
to be set for TCP Drivers. To activate these modifications
in both these cases, you will need to restart Runtime.
|
30371 |
OPC Communication |
A new "OPCUAClientLog"
DWORD32 value has been added to the 'General' Registry
Key (Default value = '0') to allow the activation of a
low level OPC UA Client activity Log. When the log
is activated, a "uaclient.log" file will be
created and additional messages will be reported in the
standard "OPC UA Client.log" log, both of which
are in the Project's LOGS folder.
|
30765 |
Design |
Added "MFCWebBrowser2"
ActiveX with Micorsoft WebView2 support to implement a
Browser Object based on Chromium Embedded Framework and
allow HTML5 navigation. ActiveX is not compatible with
Windows 7.
|
31499 |
Design |
Added new WebBrowserHTML
Symbol in the "Web Objects" Symbol Library based
on the "MFCWebBrowser2" ActiveX.
|